A new custom integration called Toshiba AC (Modbus) has appeared on the Home Assistant community forum. It gives local control of Toshiba residential air conditioners through the BMS-IFMB1280U-E Modbus interface, plus one TCB-SSRL011UUP-E RAC adapter per indoor unit. The author says there is no cloud, no vendor account and no remote API involved. It is at version 1.0.2, licensed Apache-2.0, and the author says it has been tested on their own installation only.
What it gives you
- A climate entity per indoor unit: power, setpoint, mode, fan and swing. The fault check code is decoded into text, outdoor-unit faults included.
- Controls the remote has and the cloud app hides: power limit, Hi-Power, ECO, Quiet FCU, Silence CDU and the six remote-controller locks, as select and switch entities.
- A device per indoor unit plus one for the interface, with model, serial number, a connectivity sensor and bus diagnostics that help tell a noisy RS-485 line from a second master on the gateway.
- Optional outdoor-unit power, energy and Running sensors, taken from any power meter on the outdoor unit’s supply. The interface itself reports nothing about the outdoor unit.
- Units added later are found by a button or a background scan, with no restart.
How it differs from the built-in Modbus integration
The author is clear that the core modbus integration works and is faster for a first test. Their comparison says it creates no registry devices, spends 96 frames per poll on three units (this one uses 21 by merging reads), has no select entities for power limit or remote lock, and shows a missing indoor unit as a valid frame of zeros, which looks like real data. This integration marks that unit unavailable instead. It borrows its Modbus link from the core integration, so the two can run side by side.
What to check before installing
- Hardware first. This is not for a typical split system with only a Wi-Fi module. You need the BMS-IFMB1280U-E interface, a RAC adapter on every indoor unit, and an RS-485 gateway reachable over the network.
- Home Assistant version. It needs 2026.9 or newer.
- Setup details. The setup flow asks for the gateway address, the framing, and the slave address set on switch SW1 of the interface. The project documentation has an installation page covering interface settings that decide whether it works; read it before you buy anything.
- Bus hygiene. The diagnostics mention a noisy RS-485 line or a second master on the gateway. If something else already talks to that interface, sort that out first.
- Lock it down. A Modbus gateway on your network has no built-in authentication, so keep it on a trusted segment.
Install is through HACS: the project says it is in the default store, or you can add the GitHub repository as a custom repository or use the release zip, then restart and add the integration. You can try the setup flow without an air conditioner using the included emulator, a dependency-free Modbus RTU-over-TCP server that mimics three slave addresses and a missing unit.
Our take
This is a niche but useful project for anyone who has a Toshiba system already wired with the Modbus interface, especially where the alternative is the vendor cloud. With one author, one tested installation and a version number just past 1.0, treat it as early. Try it alongside the core modbus setup rather than replacing a working one, and report your Toshiba model on GitHub if it works, since the author is asking for exactly that. If you are choosing equipment from scratch, check that your exact indoor and outdoor models are supported by the interface before buying.
Sources for this story: the forum thread and the GitHub repository. The project is not affiliated with Toshiba.