If your building runs an ICT Protege access and alarm controller, there is a new option for bringing it into Home Assistant. A community member posted ICT Protege Enhanced, a fork of the existing Protege integration. The fork credits the original author, caboose014, for the protocol work and says its own changes came out of testing against a Protege WX. It is an independent project, not an official ICT product.
What it does
The integration talks straight to the controller’s Automation and Control service, normally on TCP port 21000. Nothing goes through a vendor cloud. According to the post, you get:
- Door lock and unlock controls, contact state and combined door/lock information.
- Area Arm Away, Disarm and alarm status.
- Input state, trouble entities and bypass controls, plus output (PGM) control.
- Everything grouped under one controller device, with a searchable discovery list and an “Add all visible” option.
- Automatic reconnect and a Controller Online sensor. When communication drops, the other entities go unavailable.
On a WX, you can optionally supply web-operator credentials so the integration can look up your programmed names, instead of falling back to probing the service. Those credentials are separate from the Automation Service PIN. The names lookup only reads metadata, while control permissions come from the Automation Service user.
What to check before you install
- Encryption. The fork currently supports only the Automation Service setting with Encryption Level: None. The author says to keep that connection on a trusted local network and never expose it publicly. For a security panel, that is worth taking seriously: keep it off any shared or guest VLAN.
- Connection monitoring. A silently dead connection can take the existing 180-second watchdog interval to be noticed. The author advises validating behaviour on your own controller before relying on the online status for anything critical.
- WX versus GX. The changes have focused on WX. The author specifically asks for feedback from GX owners, so treat GX as less proven.
- Licensing and firmware. The fork’s post doesn’t cover this. The original project’s README says its control service needs the Automation and Control licence, and that without it the integration can run through the WX web interface instead. It lists Home Assistant 2025.1 or later and WX firmware 4.00.1676 or later for that version, and notes that the panel allows one connection per service, so Home Assistant should not share a service with another system. Check the fork’s own requirements before assuming the same applies.
Installation goes through HACS as a custom repository: add it, download, restart Home Assistant, then add the integration and enter the controller address, port and a Protege user PIN. A My Home Assistant link will open the repository in HACS on your instance.
Our take
Local control with no cloud is the right design for an alarm panel, and a fork that actively tracks real-world quirks is welcome. But this is a young, single-maintainer project controlling doors and arming. We would not make it the only way to arm or secure a site, and we would not build automations that unlock doors on the strength of it until you have tested it for a while. Keep your keypads and normal credentials as the primary path, use Home Assistant as a convenience layer, and have your security installer involved if the panel changes are outside your comfort zone.
If you do try it, the author asks you to report controller model, firmware and integration version in the forum topic, and to scrub PINs and credentials from any logs you post.