A new custom integration for the Husdata H66 heat pump gateway showed up on the Home Assistant community forum on November 16. It talks to the H66 over Modbus TCP and replaces the climate “thermostats” the H66 creates for its settings through MQTT discovery with ordinary sensors, binary sensors, numbers, switches and a button. It is a community project with no stars or forks yet, so treat it as early. This is our read of the project pages, not hands-on use.
What you get
- Temperatures, operating hours, power and energy as sensors.
- Compressor, pumps, switch valve and alarm as binary sensors.
- Settings as numbers and switches with real limits and units, for example room temperature setpoint at 5 to 29 °C.
- An alarm reset button, which turns the heat pump off for 10 seconds and on again.
The author tested it with an IVT Greenline using a Rego 600 controller. It reads the register map from the H66 web page, so other heat pumps the H66 supports should work, but that is not confirmed.
Before you start
Modbus TCP is off in the H66 by default. The author’s instructions: open the H66 web page, go to Config, then Modbus, set MODBUS_PORT to 502, and restart the H66.
The H66 accepts only one Modbus client at a time. Home Assistant holds its connection open, so any other Modbus tool will be locked out while this integration runs. The H66’s MQTT output is separate and keeps working, so existing MQTT setups are not disrupted.
What to check before installing
- Home Assistant version. It uses Home Assistant’s own Modbus connection handling, which needs 2026.10 or newer. Older versions are not supported.
- Install route. On 2026.11 or newer you add the repository as a custom repository in the Marketplace. On 2026.10 you use HACS the same way and restart. A manual copy into custom_components also works.
- Register addresses can move. The H66 numbers registers one per parameter in home page order, so addresses depend on your heat pump and can shift after an H66 firmware update or when you add custom registers. The integration rereads the map at startup and falls back to the last stored one if the page can’t be read. Still, we would hold off on H66 firmware updates until you have confirmed the entities survive.
- Known rough edges on a Rego 600. The Extra hot water setting does not work yet, because the heat pump resets it to 0 after about 20 seconds. The External control switch can’t be read back and Husdata warns it can behave unpredictably, so it is disabled by default. Accumulated consumption restarts at 0 when the H66 boots, which the Energy dashboard handles.
What it means for an installed system
If you already have the H66 feeding Home Assistant over MQTT, nothing forces a change. The case for switching is cleaner entities: real units and limits instead of thermostat entities standing in for settings. Because the MQTT output keeps working, you can try this alongside it. Note that power and energy figures are calculated by the H66 from wattages you enter on its web page, so they are estimates, not metered readings.
This is also a local path from end to end: Modbus TCP across your own network, no vendor cloud involved. As with any early community integration, there is no promise of long-term maintenance, so keep a backup before you start, and do not rely on it for anything where a bad write would matter until you have watched it run for a while.
The project is on GitHub and was announced in the Home Assistant community thread by Jonny Bergdahl.