A new custom dashboard card for Home Assistant lets you edit the weekly time programs of a Vaillant heating controller without the vendor app or its cloud. The Ebusd Time Program Card was posted to the Home Assistant community forum on November 7, 2026 by its author, who goes by citoki (Steffen). It works over ebusd and MQTT, so everything stays on your own network.
What it does
The card is aimed at the Vaillant sensoCOMFORT VRC 720 controller (ebusd circuit ctlv2). Its layout follows the vendor’s iOS app, which the author admits openly. According to the project page, it offers:
- Heating zones 1 to 3, hot water and circulation, each on its own tab
- Editing several days at once (Mo to Fr, Sa to Su, or any days you pick)
- Up to 3 slots per day on the controller’s 10-minute grid, with a temperature per slot
- Checks before writing for overlaps, an end time before the start, and out-of-range temperatures
- Verified writes: each day is read back from the controller, and if one does not match you can retry, continue or restore the previous program
- A read-only preview mode that shows a compact week overview with a marker for the current time
- A dark design of its own, or your Home Assistant theme, plus 14 languages (machine-translated, corrections wanted)
The author’s reason for building it is practical. On a heat pump, they only tweak the time program in mild weather, for example starting heating later on a warmer morning or pausing it over lunch. Before this, they did that through automations on the cloud-based sensoNET route. Writing raw messages to ebusd by hand was tedious, hence the card.
What you need first
The card does not talk to the heating system itself. You need a working ebusd setup: an eBUS adapter, ebusd running with message definitions, and MQTT with Home Assistant discovery. The project page points to an eBUS adapter and the ebusd configuration from john30’s projects. It also says the upstream configuration reads only the first time slot of each day, and hot water without a temperature, so the card needs a local copy with additions to get all three slots.
The author also warns that the full stock configuration exposes so many entities that the eBUS cannot read them all in time. They saw delays of around 20 minutes until they cut the list to what they needed and set proper polling intervals. If your values look stale, that is the first thing to check.
Once sensors such as sensor.ebusd_ctlv2_z1timer_monday0_htm appear in Home Assistant, the card needs only type: custom:ebusd-time-program-card.
What to check before you try it
- Your hardware. It was tested on a Vaillant aroTHERM plus 55/6 heat pump with a VR 71 wiring centre and a VRC 720 controller, covering zone 1, hot water and circulation. Zones 2 and 3 use the same messages but are untried on a real system. Other Vaillant setups are unconfirmed, and the author asks for reports.
- Writes go to your heating controller. The read-back check is reassuring, but start with the preview mode and one small change.
- Install route. It is not yet in the default HACS catalogue; it is in the review queue. On Home Assistant 2026.11 the author says to use Settings, Marketplace, Add from link. On older versions, add it as a custom repository in HACS with type Dashboard. Manual install is also described.
- Maturity. The repository shows no stars or forks yet, so treat it as a new, single-author project under an MIT licence.
Our take
This is a good example of the local-first approach: MQTT and ebusd keep the schedule in your house, not on a vendor server. It only makes sense if you already run, or are willing to run, the ebusd hardware and configuration. If you do, it removes a real annoyance. If you do not, it is not a reason to buy an adapter on its own.
Details and issues are on the GitHub repository, and the original write-up is in the Home Assistant community thread.