A community member has published an ESPHome project that brings Immergas heat pumps and gas boilers into Home Assistant locally. It started as a forum question about getting a MAGIS COMBO V2 connected and grew into a hub covering much of the Immergas range. It is an independent project, not made or supported by Immergas, Samsung or Midea.
What was announced
The hub is one ESPHome device, an M5Stack AtomS3 Lite plus an RS485 or OpenTherm adapter. The author says the parts are off the shelf and cost a few tens of euros in total. It talks to the buses inside the unit and passes them to Home Assistant with no cloud and no MQTT.
Which bus you use depends on the unit:
- MAGIS PRO V2 / COMBO V2: Modbus D+/D-, BMS T-/T+ and Samsung NASA F1/F2. The project lists these as stable.
- VICTRIX ZEUS, EXA, TERA, OMNIA, HERCULES: OpenTherm, either replacing the room unit or as a gateway that keeps it. Experimental.
- Newer gas boilers and MAGIS M TOP: Generator BMS over Modbus RTU. Experimental.
- MAGIS M (Midea-based): Midea M-Thermal Modbus on H1/H2. Experimental.
- TRIO HYDRO: configuration ready but untested, and testers are wanted.
On top of that sit Lovelace cards that find the entities themselves, so a full dashboard is one line of YAML. They show COP now and today, heat output, compressor and burner runtime, heating curves with draggable points, the boiler’s four calendars, and the cost of 1 kWh of heat from each source. Labels follow the Home Assistant language, in 11 languages.
If you only have the Immergas Dominus Wi-Fi module, there is a separate HACS integration that talks to it over local TCP with no extra hardware.
What it means for an installed system
The honest caveat is testing. The author built and tested everything on one Magis Combo 9 Plus V2 with an Audax Pro 9 V2 outdoor unit. Everything else follows manuals and community findings and is waiting for first installations. Owners of other models would be early testers, and the author asks for reports, including “it doesn’t work”.
An earlier forum thread by the same author shows the road here was bumpy. A Samsung-protocol integration on F1/F2 gave a stable connection but wrong room temperatures, non-working hot water metering and COP, and no on/off or winter/summer switching. The new hub’s use of D+/D- and T-/T+ appears aimed at those gaps, but we have not seen it proven beyond that one setup.
Things to check before you try it:
- Find your model in the README table. Stable, experimental and untested are very different propositions.
- Mind the warranty. The project warns that connecting third-party hardware may affect it. Ask your installer first.
- Respect the mains. The buses sit inside mains-powered units. Disconnect power before opening anything and leave the wiring to someone qualified.
- Do not expect the cloud. The hub and the Dominus integration are local only, on purpose, so the Dominus app features stay separate.
- Skip unsupported buses. The older CAR-Bus (Super CAR, terminals 42/43) is not supported. The project points those boilers to the OpenTherm terminals instead.
For wiring, use the per-model pages in the project’s documentation rather than anything secondhand. We have not used this hub ourselves.
Our view: if you have a MAGIS PRO or COMBO V2, this looks like the most complete local route we have seen, and it costs little to try. If you have anything else, wait for tester reports or be ready to send logs. Do not pull working heating controls out for an experimental bus.
Sources: the announcement thread, the GitHub project, and the earlier Modbus thread.
Sources
- Immergas heat pumps & boilers in Home Assistant – MAGIS PRO/COMBO V2, MAGIS M, TRIO, VICTRIX/ZEUS (Modbus, BMS, Samsung NASA, OpenTherm)
- How to connect to IMMERGAS Magis Combo V2 / Magis Pro V2 heat pump via MODBUS into HA
- GitHub – jotuera/immergas-modbus-bms-nasa-opentherm-hub: One ESPHome device for Immergas heat pumps and boilers: D+/D- Modbus, T-/T+ BMS, F1/F2…