A new custom dashboard card for Home Assistant is aimed at owners of heat pumps connected through EMS-ESP, the interface used with Bosch, Buderus, Nefit and other EMS heat pumps. The author posted it on the Home Assistant community forum on November 5, 2026, and says it shows what the manufacturer’s app shows, but from your own data inside Home Assistant.
What the card shows
- Energy consumed and heat produced, split into heat pump, backup heater and environmental energy, for today, this month, any calendar year or the lifetime of the unit.
- A monthly history with bars per month, monthly mean outdoor, flow and hot water temperatures, and a performance factor for each month.
- A seasonal performance factor (SPF) per year for total, heating and hot water, plus the backup heater’s share.
- CSV export, English and German interfaces, light and dark themes, and a phone-friendly layout.
How it works
The card reads only Home Assistant’s own long-term statistics of the EMS-ESP counters. According to the project page, it needs no template sensors, no utility_meter helpers and no cloud connection, and it never writes anything to the heat pump. With the default EMS-ESP entity names, the configuration is a single line: the card type. Other entity IDs can be set if yours differ.
Two details are worth knowing. First, energy consumed is calculated as compressor plus backup heater, not from the "total" meter. The author found that after a gap in the recorder, the long-term statistics of the total meter lost a jump of about 60 kWh while the partial counters kept it. Second, the EMS-ESP heat counters already include the backup heater’s heat, so the backup heater counts against the performance factor and environmental energy is not overstated.
To keep loading quick, closed months are cached in Home Assistant’s per-user frontend storage, readable only by logged-in users. On the author’s MariaDB recorder, loading drops from about 25 seconds to under a second with a full cache.
What to check before installing
- Your heat pump. It has only been tested on one Buderus Logatherm WLW186i with an MX300 gateway, on Home Assistant 2026.10. On that unit, today’s, this month’s and this year’s values matched the Buderus app to within 0.5 kWh. Other EMS heat pumps that expose the same counters should work, but this is not verified. The author is asking owners of other models to report whether the counters behave the same way.
- Statistics classes. The energy sensors need state_class total_increasing and the temperature sensors need measurement, so the recorder keeps long-term statistics. The project page says EMS-ESP does this by default.
- MQTT discovery. EMS-ESP needs to be feeding Home Assistant through MQTT discovery, since the default entity IDs come from there.
- Your history. The card can only be as good as your statistics. The lifetime view uses current counter states, so it includes energy from before Home Assistant started recording. In summer, the heating counter can keep rising on standby and pump power while almost no heat is produced, giving very low heating performance factors. The card flags those months.
Installing it
It installs as a HACS custom repository of type Dashboard, or manually by copying the JavaScript file into the www folder and adding it as a dashboard resource. It works best on its own dashboard view of type Panel. The code is on GitHub and the announcement is on the Home Assistant community forum. The project is a community effort, and issues and pull requests are welcome.
Our take
This is a nice example of the local-first approach: no vendor cloud, no extra helpers, and a view of heat pump efficiency that is yours to keep. It is a young project with a single tested machine behind it, so treat early numbers as something to compare against your manufacturer’s app for a few days before trusting them. If you run a different EMS heat pump and the figures line up, telling the author is the most useful thing you can do. A read-only card also carries little risk to the heat pump itself, which is a point in its favour.