A community member has published a custom Home Assistant integration for the Anker Solix P1 Energy Tracker that talks to the device directly over your local network. According to the forum announcement, it reads the device’s raw DSMR data and needs no Anker cloud account or internet connection.
What it does
The author lists these features:
- Live consumption and production
- Energy import and export
- L1, L2 and L3 measurements
- Gas, water and other M-Bus meters
- Configurable polling
- Anker diagnostic counters
The GitHub README explains the method. The integration polls a local HTTP endpoint on the device at an interval you choose, from 5 to 300 seconds. It pulls the raw DSMR telegram out of the response, checks its CRC, and only then updates the entities. It does not use Anker’s cloud API.
You choose single-phase or three-phase validation by hand. If a bad frame arrives, the integration keeps the last valid values for up to 15 seconds. If good data does not return, the affected entities go unavailable. With debug mode on, it logs the reason and a redacted copy of the telegram straight away. The log can tell apart HTTP or JSON failures, missing data, a bad CRC, missing required fields, empty or malformed values, and unexpected units.
How to install it
It is a HACS custom repository, not part of Home Assistant core. The README steps are: add the repository to HACS, install Anker SOLIX P1, restart Home Assistant, then add the integration under Settings -> Devices & Services. A manual copy of the custom_components/anker_solix_p1 folder also works. The configure dialog lets you change the hostname or IP address, and a new address is probed before it is saved.
What it means for an installed system
Local reading is the main appeal. HA’s own reasoning on cloud dependence is that a cloud service does not work if the internet is down or the company stops support. A local endpoint avoids that for this device.
The cautions are real, though:
- It is unofficial. The README says it is not affiliated with, endorsed by or supported by Anker. A firmware update that changes the local endpoint could break it, and nobody at Anker is obliged to care.
- It is new. The author says feedback from people with different meters is welcome. The repository shows 0 stars and 0 forks, so there is almost no track record yet.
- Phase mode is manual. Pick the wrong one and validation will fail.
- Static address. Because it polls by hostname or IP, give the P1 a DHCP reservation so the address does not drift.
Our take
If you already own the device and want its numbers in the Energy dashboard without an Anker account, this is worth a careful try. Install it on a system where a missing sensor is an annoyance, not a problem, and note your polling interval. We have not used it ourselves. If you are still deciding what to buy, we would not choose a meter because of an integration with a few days of history. Wait for reports from other meter types first.
Since it is a custom integration, take a backup before installing, as with any HACS add-on, and check the repository for issues after each Home Assistant update.